ENERTRONIC I-10KVA-Industrial UPS power supply
ENERTRONIC I The UPS power supply provides uninterrupted power with significantly improved voltage and frequency quality for system loads. In normal operation, the load is powered by the input transformer, rectifier, inverter, and output transformer. The ENERTRONIC I series is designed to meet the highest level of UPS, VFI SS 111, and complies with EN 62040-2. |
![]() |
ENERTRONIC I-10KVA | |
Capacity | 10KVA |
Power/Factor | 8KW/0.8 |
Input Voltage | 110V/220V/380V/480V |
Output voltage | 110V/220V/380V/480V |
Transformer | Output isolation, output isolation, bypass isolation |
Battery DC | 110V/192V/220V/384V |
Number batteries | 16/18/32 Pcs |
Type of rectifier | 6pulse / 12pulse |
IP | IP42 |
size | 600*600*1800mm / 800*600*2200mm |
One cabinet | Host integrated cabinet |
Two cabinet | Main cabinet、Bypass feeder cabinet |
Three cabinet | Main cabinet, bypass cabinet, distribution cabinet |
Due to the use of the latest IGBT transistor technology in both rectification and inversion, the new ENERTRONIC I series provides the highest level of power reliability while ensuring system economy. The input power factor of UPS is ≥ 0.99, and the total harmonic distortion of the input is<5%. The inverter design of the ENERTRONICI series UPS is excellent, and the dynamic output voltage offset value is very small even under 100% load variation. The combination of 16 bit microprocessors and the latest power electronics technology ensures high reliability in the control and monitoring of all rectifiers, inverters, and static electronic bypasses. Static electronic bypass and manual bypass switches are integrated into the equipment. The front of the cabinet is equipped with a plastic film keyboard, which has six buttons, four three color and two monochrome light-emitting diodes, and a system simulation operation diagram.
function
UPS power supply provides uninterrupted power supply with significantly improved voltage and frequency quality for system loads.
In normal operation, the load is powered by an input transformer, rectifier, inverter, and output transformer.
The ENERTRONIC I series design meets the highest level of UPS VFI SS 111 and complies with EN 62040-2.
rectifier
The three-phase mains power is converted into adjustable and stable DC voltage through self coupling or isolation transformers and rectifiers, providing DC power for the inverter and charging and float charging power for the battery, ensuring that the battery is in the best working state; The rectifier adopts the most advanced IGBT technology and is equipped with an input power factor correction circuit (power factor=1), which results in almost zero interference and pollution of the equipment to the power grid, reducing system investment and operating costs after operation. The rectifier provides full load power to the inverter and can recharge the discharged battery to 95% of its capacity within 12 hours. The rectifier is equipped with a software controlled soft start function, which can slowly boost and restart after a mains power failure without causing any impact on the power grid. The restart of the parallel system is carried out alternately to ensure that all UPS systems do not start simultaneously. The rectifier has IU characteristics, meets the requirements of battery manufacturers, and has optional battery temperature compensation to maximize battery life.