BEINING UPS Power Choice

BEINING UPS Power Supply Selection Guide
(Based on application scenarios, power requirements, performance metrics, and after-sales support, the industrial-grade ENERTRONIC I series is recommended as the core solution for its modular design, high reliability, and wide temperature adaptability.)
I. Application Scenarios & Power Requirements
- Industrial Automation Production Lines
- Requirements: Millisecond-level power backup for PLCs, sensors, and other critical equipment to prevent production halts due to data loss.
- Recommended Model: ENERTRONIC I Series (10KVA–200KVA)
- Supports 3-phase input/1-phase output.
- Dynamic response time <10ms, voltage deviation ±1%.
- Power Plants & Nuclear Power Stations
- Requirements: High-reliability power for monitoring systems and excitation systems to avoid data loss or generator excitation failure.
- Recommended Model: ENERTRONIC I Series (Nuclear-Grade Certified)
- Meets IEEE, RCC-E, IEC, and Westinghouse standards.
- MTBF >250,000 hours, operates in -15°C to 50°C environments.
- Data Centers & Telecom Base Stations
- Requirements: Modular design for N+1 redundancy, low PUE, and uninterrupted data transmission.
- Recommended Model: ENERTRONIC III Series
-
Supports parallel operation and extended battery runtime.
-
II. Key Performance Metrics
- Input Specifications
- Voltage Range: 380V/400V/415V ±15%, frequency 50Hz/60Hz ±10%.
- Power Factor: ≥0.99, input THD <5% (reduces grid interference).
- Output Specifications
- Voltage Stability: <±2% voltage drop during 0–100% load changes, stabilization time ~1ms.
- Overload Capacity: 150% rated current for 60 seconds, 120% for 10 minutes. Short-circuit current up to 3× rated value.
- Battery & Runtime
-
Battery Types: Supports lead-acid, VRLA, and Ni-Cd batteries (optional Li-ion expansion).
-
Charging Efficiency: IGBT-based rectifier recharges discharged batteries to 95% in 12 hours. Temperature compensation supported.
-
III. Reliability Design & Environmental Adaptability
- Modular Architecture
- Independent charger and inverter modules support hot-swappable replacement.
- Integrated static bypass switch and manual bypass for seamless fault transfer.
- Protection Level
- IP20 Standard: Dust and pollution resistance for industrial environments.
- Redundant Ventilation: Forced cooling design supports continuous operation at 50°C.
- Nuclear-Grade Certification
-
Compliant with IEEE, RCC-E, IEC, and Westinghouse standards for harsh environments.
-
IV. Intelligent Management & Scalability
- Communication Interfaces
- Supports Modbus, Profibus, Ethernet, and SNMP for integration with SCADA, ESD, DCS, and BMS systems.
- Standard RS232/RS485 interfaces; optional Profibus and TCP/IP.
- Remote Monitoring
- Real-time battery status and system alert tracking.
- Fault prediction and event logging (stores up to 1,200 events).
- Intelligent balancing adjusts individual battery states (discrepancy <3%).
- Scalability
-
Parallel operation supported for future capacity expansion via additional battery packs and power modules.
-
V. Brand Reputation & After-Sales Support
- Market Credibility
- Founded in 1938, BEINING (Germany) specializes in industrial-grade UPS systems with over 20,000 installations worldwide.
- Localized services in China via Beijing Soronsen Technology, combining German engineering with Chinese market needs.
- After-Sales Services
-
National Service Network: 28 provincial spare parts warehouses with 4-hour emergency response.
-
Battery Recycling: 99.8% lead recovery rate reduces environmental costs.
-
VI. Recommended Models & Configuration Tips
Model | Power Range | Ideal Scenarios | Core Advantages |
---|---|---|---|
ENERTRONIC I | 10KVA–200KVA | Industrial automation, nuclear plants | Nuclear certification, wide temperature range, modular design |
ENERTRONIC III | 10KVA–200KVA | Data centers, telecom bases | N+1 redundancy, low PUE, scalability |
Thyrotronic | 3kW–120kW | DC power systems | High-precision rectification, multi-battery support |
Selection Tips:
-
For industrial automation or nuclear plants, prioritize the ENERTRONIC I series for its reliability and modularity.
-
For data centers or telecom bases, choose the ENERTRONIC III series for redundancy and energy efficiency.
-
Ensure UPS capacity is 120%–130% of peak load to reserve redundancy.
Final Recommendation:
BEINING’s ENERTRONIC I series offers the best balance of cost, performance, and adaptability for most industrial applications, while the III series excels in data-intensive environments. Always verify compatibility with local grid standards and consult BEINING’s technical team for customized solutions.